Sewage Pump Stations by Alton Pumps

Package Sewage Pump Stations in Stock

Compare the complete AFM and AFPS range of single- and twin-pump package sewage stations from 200 to 5,300 litres. All 26 listed models are in stock and normally dispatched within 2–3 working days.

In stock

26 package pump stations ready to specify

All listed pump stations are in stock. Orders received by 2pm UK time, Monday to Friday, are normally dispatched within 2–3 working days, followed by 2–3 working days in transit: allow 4–6 working days overall. Orders received after the cut-off are counted from the next working day. Standard UK delivery is £56 + VAT (£67.20 including VAT) for every listed model.

Configure a quotation

AFPS5

In stock

AFPS5 – 2,400-litre single-pump sewage pump station

Base station price£1,806.20 + VAT

Standard UK delivery: £56.00 + VAT

Selected extras are priced separately. We confirm the final pump duty, specification and lead time before order.

Single-pump Maxi-range tank cutaway with pump and discharge pipework
Range photograph — tank size, pump and fittings are confirmed in your quotation.
How a pump station works
Illustrated overview of a house, underground pump station and discharge pipework
Illustration only—not a photograph of the selected model or an installation drawing. Tank layout and equipment vary.
Tank capacity
2,400 litres
Pump configuration
Single pump
Normal dispatch
2–3 working days
Selection check required

Capacity alone does not confirm the pump duty or package. We check flow, head, inlet depth, rising main, power supply and site conditions before order.

Buy the standard base station

Ready for secure online payment?

Standard station: £2,167.44 including 20% VAT

£2,234.64 including 20% VAT and standard UK delivery

This purchase is for the standard base station with one 50mm solids-handling vortex pump, 6m maximum head. Higher-head and macerator pumps are quoted upgrades. Maximum head is not the operating duty: we check the required flow and head for your installation.

Technical extras, commissioning, installation and civils are quoted separately.

Buy standard station securely

Need options or a specification check? Use the quotation form alongside this panel.

Choose another model
Add requirements to your quotation

Choose any requirements you want included in the quotation. We check that selected extras are compatible with the station. The displayed base station price and standard UK delivery charge exclude VAT; selected extras are priced separately. Final specification and lead time are confirmed in writing.

This requests a quotation, not an order. Your selected extras carry through to the enquiry form.

AFM compact single-pump stations

Four compact single-pump chambers from 200 to 600 litres.

AFPS single-pump stations

Eleven single-pump package stations from 800 to 5,300 litres.

AFPS twin-pump stations

Eleven twin-pump package stations from 800 to 5,300 litres.

Before ordering

Capacity alone does not select a pump station. Send the site postcode, pumped liquid, expected flow, inlet depth, discharge point, static and friction head, rising-main details, power supply and any control or alarm requirements so the pump duty and complete package can be checked before order.

Help me choose a pump station
Practical answer

The catalogue contains 26 in-stock AFM and AFPS package sewage pump stations from 200 to 5,300 litres, with single- and twin-pump configurations and normal dispatch within 2–3 working days. Final selection still depends on flow, head, inlet depth, rising main, controls and site conditions.

What a package pump station normally includes

A package pump station brings the chamber, pumps, internal pipework, valves, guide rails, floats, access cover, control panel and alarm arrangement into one coordinated pumped drainage system. The right package depends on incoming flow, pumped head, storage volume, solids handling, access, ground conditions, power supply and future maintenance requirements.

Foul sewage, grey water and surface water packages

Package stations are not all the same. A foul sewage station needs pumps and pipework suitable for toilet waste and solids handling. A grey water station may deal with basins, showers, laundries or welfare flows. A surface water station may need to manage storm water, rainwater or clean water flows with different storage and pump duty considerations.

  • Foul sewage package pump stations
  • Grey water and light wastewater pump stations
  • Surface water and storm water pump stations
  • Rainwater lifting systems
  • Domestic and micro package pump stations
  • Commercial and developer pump station packages

Pumps by Alton Pumps, civils by AFS where needed

Alton Pumps can support the pumping side: pump selection, pumps, panels, floats, alarms, valves, commissioning and servicing. Where the project also needs excavation, concrete bases, chamber installation, trenching, rising mains, ducting or reinstatement, Alton Facility Services can support the civil installation package.

Avoiding poor package station specification

Many repeat pump station faults start with the wrong specification. Common problems include undersized chambers, poor pump duty selection, unsuitable float spacing, lack of emergency storage, poor lifting access, weak covers, incorrect rising main sizing, bad valve access and panels located where they cannot be safely maintained.

Practical pump station guidance

This page answers the practical questions people ask before they call: what the pump station is used for, what can fail, what details are needed, how the equipment and civil scope split, and when the likely route is repair, servicing, refurbishment, replacement or installation.

How we can help

  • Package pump station selection and replacement
  • Single and twin pump arrangements
  • GRP, HDPE and concrete chamber options
  • Foul sewage, grey water and surface water systems
  • Controls, floats, alarms and telemetry advice
  • Civil installation support through Alton Facility Services where required

Frequently asked questions

Are the listed package pump stations in stock?

Yes. All 26 listed AFM and AFPS models are currently in stock and normally dispatched within 2–3 working days. Availability and delivery timing are confirmed with the quote.

Which pump station model do I need?

Capacity is only one part of the selection. Send the expected flow, inlet depth, pumped liquid, discharge point, rising-main details, static and friction head, power supply and site postcode so the pump duty and package can be checked before order.

Can you help with package pump stations?

Yes. Send the site postcode, photos, pump details, control panel photos and a brief description of the issue or planned works.

Can Alton Facility Services support the civil works?

Yes, where excavation, chamber installation, pipework, concrete bases, rising mains or reinstatement are required, Alton Facility Services can support the civil installation package.